ادوارد

تعداد بازدید:۲۲۳۰

Edwards Logo

  •  

Mitral valve repair

Carpentier-Edwards Physio II ring

Invented by Alain F. Carpentier, MD, PhD and David H. Adams, MD

Repair without limits

Ease for every implant

  • Designed by surgeons to improve the implant experience including suture management, ring placement and assessment of the repair
  • Angled holder improves visualization and line-of-sight to the mitral valve

Indicated for use in patients with mitral valve insufficiency

 

Carpentier-Edwards Physio II annuloplasty ring

 

 

Carpentier-Edwards Physio II ring profile view

 

 

Global shape optimization

  • Evolves from the native D-shape to a more circular shape to accommodate the pathological changes in mitral annular dimensions

 

Pause

Physio II Annuloplasty Ring

Physio II Ring

Edwards Lifesciences Global Shape Optimization

  •  
  •  
  1. pii_image.png?v=636421105340000000
  2. physioii_brandbook05-hr-1.png?v=636421105340000000
  3. physioii_mediaslider.png?v=636421105350000000

Models & specifications

Accessories

Carpentier-Edwards Physio ring

Provides the advantage of the remodeling concept while preserving flexibility

  • Remodeling preserves 3:4 ratio between the anteroposterior diameter and transverse diameter during systole
  • Restores anatomical size and shape to provide optimal orifice area
  • Progressive posterior flexibility allows for physiologic contractility of the mitral valve annulus during systole

 

 

Carpentier-Edwards Physio annuloplasty ring side view

 

CARPENTIER-EDWARDS PHYSIO ANNULOPLASTY RING SIDE VIEW

Pause

CARPENTIER-EDWARDS PHYSIO ANNULOPLASTY RING

Carpentier-Edwards Physio Annuloplasty Ring

  •  
  •  
  1. frontview_mediaslider.png?v=636421105360000000
  2. sideview_mediaslider.png?v=636421105370000000

Models & specifications

Accessories

Model Description Compatible with Ring Model Sizes
1174 Sizer - Individual 4450 24, 26, 28, 30, 32, 34, 36, 38 and 40 mm
TRAY1174 Sterilization Tray 4450 N/A
1150 Reusable Handle 4450 N/A
1111 Reusable Sizer Handle 4450 N/A
1126 Single-Use Sizer Handle 4450 N/A

 

 

Important safety information 

Important safety information 

Caution: Federal (United States) law restricts this device to sale by or on the order of a physician.
See Instructions For Use (IFU) / Directions For Use (DFU) for full prescribing information, including indications, contraindications, warnings, precautions and adverse events.

Edwards Logo

  • Follow Edwards on:
  •  
    •  
    •  
    •  
    •  
    •  
    •  
    •  
    •  
    •  
  •  

© 2019 Edwards Lifesciences Corporation. All rights reserved.

آخرین ویرایش۲۲ مرداد ۱۳۹۸